Information reviewed: 16 November 2026
Two area figures for the same building can differ without either being a calculation mistake. They may use different boundaries, inclusion rules or purposes. Before comparing a letting, valuation or design schedule, check what was measured and on which basis. Our floor area survey service can be scoped around the recipient’s required standard and reporting format.

First check the current standard
As checked on 16 November 2026, RICS identifies the sixth edition of the Code of Measuring Practice and/or IPMS: All Buildings as the applicable routes according to context. Its seventh-edition Code consultation is not itself a final published replacement. Older statements that every relevant instruction must use a particular archived Property Measurement edition should not be repeated without checking current guidance.
What the main terms distinguish
| Basis | Broad distinction |
|---|---|
| GEA | Gross external measurement under the selected Code rules |
| GIA | Gross internal measurement under those rules |
| NIA | Net internal measurement with specified exclusions |
| IPMS 1 | External measurement under IPMS: All Buildings |
| IPMS 2 | Internal measurement using the IPMS internal boundary rules |
| IPMS 3.1 / 3.2 | Exclusive-occupation measurement on external/internal bases |
| IPMS 4.1 / 4.2 | Selected internal areas with differing treatment of walls and columns |
These are not automatic equivalents. In particular, IPMS 2 should not simply be relabelled GIA, or IPMS 3.2 relabelled NIA. IPMS uses defined boundary and limited-use-area rules that need to be applied to the actual building.
Watch the details that change the result
Under the sixth-edition Code, low-headroom treatment differs between GIA and NIA; space below 1.5 m is not handled identically. Internal circulation also needs careful classification: “remove every corridor” is not a reliable NIA rule. The relevant definition and the function of the space matter.
For an attic, office or multi-tenant building, ask the measurer to identify unusual spaces on a plan and explain the treatment used. This is more useful than a generic claim that one basis is always a fixed percentage smaller than another.

A numerical example: why basis matters
Suppose two fictional reports give 500 m² and 480 m² for the same premises. The 20 m² difference is 4% of the larger figure. Before challenging either report, compare the basis, date, extent, boundary interpretation and exclusions.
If a hypothetical rent is expressed at £600 per m² per year, 20 m² corresponds to £12,000 per year in a simple multiplication. That is an illustration of sensitivity, not a market rent estimate or a conclusion about the rent legally payable. Lease wording, negotiation and professional advice determine the contractual position.
How to reconcile an old and a new schedule
Start with matching floor plans and a common list of areas. Confirm that both schedules include the same floors, units, mezzanines and ancillary spaces. Then compare the measuring standard and edition. Only after that should you investigate differences in the underlying measurements.
Create a reconciliation table with one row per discrepancy: location, earlier treatment, current treatment and reason. If a wall moved between survey dates, that is a physical change. If a boundary convention changed, that is a measurement-basis difference. Keeping those explanations separate prevents an unhelpful argument about which total “looks right”.
What a useful report contains
- The purpose, standard and edition used.
- A dated floor-by-floor schedule with units and reporting precision.
- Plans with area identifiers matching the schedule.
- The treatment of unusual, limited-use or inaccessible spaces.
- A clear distinction between measured figures and assumptions.
- A revision record where the layout or interpretation changes.
Request separate schedules when two bases are genuinely required. Do not derive NIA or IPMS by applying a generic percentage to GIA. Measurement technology can improve the geometric record, but it does not remove the need to choose and apply the correct rules.
Our Southend commercial case and Croydon project illustrate measured building outputs. An area certification or reconciliation exercise should be explicitly added to the appointment rather than inferred from the existence of floor plans.

Frequently asked questions
Which basis should I use for a letting?
Confirm the requirement with the agent, valuer and other relevant recipient. Building type alone is not enough to decide every instruction.
Does an accurate scan prevent an area dispute?
It can support a reliable geometric record, but disputes can concern legal extent or interpretation of the measuring rules. State the basis and record the treatment of disputed spaces.
Is an area schedule a lease plan?
No. A lease plan identifies the legal extent described in the transaction; an area schedule reports a measurement basis. Read the lease-plan guide and request a scoped quotation for the required combination.
References and review date
References checked on 16 November 2026. Requirements can change; confirm the applicable edition and project-specific requirements when appointing the team.